PRODUCT INTRODUCTION

Online Contact Type Thickness Measuring System

For measuring the thickness of fibrous sheets

Model TME-RM, TSM-RM
Method Contact type
Object Plastic sheets such as PP and PS, fibrous sheets
Principle Linear gauge / Reference roll method
Product features
  • Suitable for measuring the thickness of fibrous sheets such as nonwoven fabrics and carbon fiber sheets
  • Full-width measurement during sheet production
  • No licenses, permits, or calibration curves required -- easy to operate
  • Dedicated monitor displays thickness trend graphs, maximum, minimum, average, and standard deviation values for quick visual assessment of sheet condition
  • Unaffected by sheet material, color, or pattern
  • Direct contact measurement provides values close to those obtained with a micrometer
  • Equipped with automatic thickness monitoring function that triggers alarms when thickness exceeds preset limits
Product specifications
Measurement range 0.1~1.6 mm
Measurement width Up to 3000 mm
Measurement pitch 1 mm~ (in scanning mode)
Minimum display value 1 μm
Power supply Three-phase AC 200 V, 50/60 Hz, 1.5 kVA
Ambient temperature 5~40°C
Air pressure 0.4 MPa clean air
Sensor scanning speed Up to 100 mm/s
Line speed Up to 50 m/min

JAPANESE

INQUIRIES

Privacy Policy